Applications
SW-XX12-F0D-F Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA). The transceiver consists of five sections: the LD driver, the limiting amplifier, the digital diagnostic monitor, the DFB laser and the APD .The module data link up to 160KM in 9/125um single mode fiber.
The optical output can be disabled by a TTL logic high-level input of Tx Disable, and the system also can disable the module via I2C. Tx Fault is provided to indicate that degradation of the laser. Loss of signal (LOS) output is provided to indicate the loss of an input optical signal of receiver or the link status with partner. The system can also get the LOS (or Link)/Disable/Fault information via I2C register access.
PRODUCT SELECTION
Wavelength | xx | Clasp Color Code | Wavelength | xx | Clasp Color Code |
1470 nm | 47 | Gray | 1550 nm | 55 | Yellow |
|
|
|
|
|
|
1490 nm | 49 | Purple | 1570 nm | 57 | Orange |
|
|
|
|
|
|
1510 nm | 51 | Blue | 1590 nm | 59 | Red |
|
|
|
|
|
|
1530 nm | 53 | Green | 1610 nm | 61 | Brown |
|
|
|
|
|
|
Pin Descriptions
Pin | Symbol | Name/Description | NOTE | |
1 | VEET | Transmitter Ground | (Common with Receiver Ground) | 1 |
2 | TFAULT | Transmitter Fault. | ||
3 | TDIS | Transmitter Disable. Laser output disabled on high or open. | 2 | |
4 | MOD_DEF(2) | Module Definition 2. Data line for Serial ID. | 3 | |
5 | MOD_DEF(1) | Module Definition 1. Clock line for Serial ID. | 3 | |
6 | MOD_DEF(0) | Module Definition 0. Grounded within the module. | 3 | |
7 | Rate Select | No connection required | 4 | |
8 | LOS | Loss of Signal indication. Logic 0 indicates normal operation. | 5 | |
9 | VEER | Receiver Ground | (Common with Transmitter Ground) | 1 |
10 | VEER | Receiver Ground | (Common with Transmitter Ground) | 1 |
11 | VEER | Receiver Ground | (Common with Transmitter Ground) | 1 |
12 | RD- | Receiver Inverted DATA out. | AC Coupled | |
13 | RD+ | Receiver Non-inverted DATA out. AC Coupled | ||
14 | VEER | Receiver Ground | (Common with Transmitter Ground) | 1 |
15 | VCCR | Receiver Power Supply | ||
16 | VCCT | Transmitter Power Supply | ||
17 | VEET | Transmitter Ground | (Common with Receiver Ground) | 1 |
18 | TD+ | Transmitter Non-Inverted DATA in. AC Coupled. | ||
19 | TD- | Transmitter Inverted DATA in. | AC Coupled. | |
20 | VEET | Transmitter Ground | (Common with Receiver Ground) | 1 |
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
3. Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V.MOD_DEF (0) pulls line low to indicate module is plugged in.
4. This is an optional input used to control the receiver bandwidth for compatibility with multiple data rates (most likely Fiber Channel 1x and 2x Rates).If implemented, the input will be internally pulled down with > 30kΩ resistor. The input states are:
· Low (0 – 0.8V): | Reduced Bandwidth | |||
· (>0.8, < 2.0V): | Undefined | |||
· High(2.0 3.465V): | Full Bandwidth | |||
· Open: | Reduced Bandwidth | |||
5. LOS is open collector output should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
Absolute Maximum Ratings
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Storage Temperature | Ts | -40 |
| 85 | ºC |
Relative Humidity | RH | 5 |
| 95 | % |
Power Supply Voltage | VCC | -0.5 |
| 4 | V |
Signal Input Voltage |
| -0.3 |
| Vcc+0.3 | V |
Receiver Damage Threshold |
| 5 |
|
| dBm |
Recommended Operating Conditions
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Case Operating Temperature | Tcase | 0 | 70 | ºC | ||
Power Supply Voltage | VCC | 3.13 | 3.3 | 3.47 | V | |
Power Supply Current | ICC | 300 | mA | |||
Power Supply Noise Rejection | 100 | mVp-p | 100Hz to 1MHz | |||
Data Rate | 1250/1250 | Mbps | TX Rate/RX Rate | |||
Transmission Distance | 160 | KM | ||||
Coupled Fiber | Single mode fiber | 9/125um SMF | ||||
Specification of Transmitter
Specification of Receiver
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note | |
Input Optical Wavelength | λIN | 1270 |
| 1610 | nm | APD | |
|
|
|
|
|
|
| |
Receiver Sensitivity | PIN |
|
| -33 | dBm | Note (1) | |
Input Saturation Power (Overload) | PSAT | -6 |
|
| dBm |
| |
LOS De-assert | LOSD |
|
| -34 | dBm |
| |
LOS Assert | LOSA | -40 |
|
| dBm | Note (2) | |
LOS Hysteresis |
| 0.5 | 2 | 6 |
| dB |
Note (1): A (TX) + B (RX) = 300mA |
| (Not include termination circuit) |
SW-XX12-F0D-F transceivers support the 2-wire serial communication protocol as defined in the SFP MSA. It is very closely related to the E2PROM defined in the GBIC standard, with the same electrical specifications.
The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information.
Additionally, SFP transceivers provide a unique enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage .It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.
The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backward compatible with both the GBIC Specification and the SFP Multi Source Agreement.
The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.
Digital diagnostics for the XGSW-XX12-F0D-F are internally calibrated by default.
Recommend Circuit Schematic
Mechanical Specifications (Unit: mm)
Appendix A. Document Revision
Version No. | Date | Description |
1.0 | 2010-09-01 | Preliminary datasheet |
2.0 | 2011-09-10 | Update format and company’s logo |
3.0 | 2014-6-7 | Update photo of Mechanical Specifications |
4.0 | 2015-2-14 | Update overload from -10 to -6 dBm |
Доставка осуществляется транспортной компанией ("Деловые линии", "Курьер Сервис Экспресс" , "Достависта") «от двери до двери». Стоимость доставки рассчитывается менеджером при оформлении заказа.
Перед отгрузкой, весь товар проходит обязательную предпродажную проверку.
Мы гарантируем что товар заказанный у нас, будет работать в полном его соответствии.
При согласовании заказа с менеджером, вы можете выбрать удобный для вас способ получения товара:
При согласовании заказа с менеджером, вы можете выбрать удобный для вас способ получения товара:
Продавец гарантирует отсутствие производственных дефектов и неисправностей Оборудования и несет ответственность по гарантийным обязательствам в соответствии с законодательством Российской Федерации.
Гарантийный период исчисляется c момента приобретения устройства и составляет:
В течение гарантийного срока Продавец обязуется бесплатно устранить дефекты оборудования путем его ремонта или замены на аналогичное при условии, что дефект возник по вине Продавца. Устройство, предоставляемое для замены, может быть как новым, так и восстановленным, но в любом случае Продавец гарантирует, что его характеристики будут не хуже, чем у заменяемого устройства.
Выполнение Продавцом гарантийных обязательств по ремонту вышедшего из строя оборудования влечет за собой увеличение гарантийного срока на время ремонта оборудования.
Условия гарантии не предусматривают чистку и профилактику оборудования силами и за счет Продавца.
Продавец не несет ответственности за дефекты и неисправности Оборудования, возникшие в результате:
несоблюдения правил транспортировки и условий хранения, технических требований по размещению и эксплуатации;
неправильных действий, использования Оборудования не по назначению, несоблюдения инструкций по эксплуатации;
механических воздействий;
действия обстоятельств непреодолимой силы (таких как пожар, наводнение, землетрясение и др.)
Продавец не несет ответственности за совместимость Программного Обеспечения с любыми аппаратными или программными средствами, поставляемыми другими производителями, если иное не оговорено в прилагаемой Документации.
Продавец не несет ответственности за любые убытки, включая потерю данных, потерю прибыли и другие случайные, последовательные или косвенные убытки, возникшие вследствие некорректных действий по инсталляции, сопровождению, эксплуатации либо связанных с производительностью, выходом из строя или временной неработоспособностью Оборудования.
Продавец не несет ответственности по гарантии в случае, если произведенные им тестирование и/или анализ показали, что заявленный дефект в изделии отсутствует, либо он возник вследствие нарушения правил инсталляции или условий эксплуатации.
В случае гарантийного ремонта/замены заполняется дефектная ведомость с подробным описанием неисправности и прикладывается к неисправному оборудованию. Доставка оборудования для гарантийного ремонта осуществляется за счет Заказчика. Обратная пересылка — за счет Продавца.
В не гарантийном случае доставка оборудования производится за счет Заказчика.
Если срок хранения готового оборудования превысил 365 дней со дня уведомления Заказчика, Сервисный центр имеет право утилизировать изделие как невостребованное без компенсации его стоимости Заказчику.